Intelligent, CAN-Bus
network capable measurement and I/O modules
Decentralised, CAN-Bus networkable, measurement modules for measuring
physical quantities.
The
CANSAS family of modules are compact, rugged and CAN-Bus network
capable. Any signal sources or sensors, such as voltage, current,
temperature, strain-gauges, ICP, RPMs, displacement etc. Can be
connected directly and transmitted over long distances without
distortion making the connection of complicated measurement lines
totally obsolete.
Within the CANSAS measurement module, the analogue signals are processed
and transformed to CAN messages. A digital signal processor (DSP) allows
computation of the signals in real time, which provides for intelligent
measurement and significant data reduction. A wide variety of functions
such as filtering, averaging, min/max, re-sampling, real-time data
reduction and much more, are available.
The
CANSAS modules are configured using an intuitive software interface that
means no specialist knowledge in CANbus technology is required. After
initial configuration the CANSAS module is connected to a sensor and
will start measuring as soon as it is powered up. The measured data is
then continuously transmitted to the CANbus at a user-specified transfer
rate.
This makes the CANSAS modules highly suitable for
integration into 3rd a party test and measurement system.
CANSAS Features:
Multi-channel, intelligent measurement data
digitalisation and transfer via CANbus
Any number of modules can be networked in
accordance with CANbus specifications
Real-time data processing and data reduction via
internal DSP
Up to 1 kHz per channel sampling rate
High resolution (up to 16 bits)
Low power consumption (approx. 2.5 W at 12 V) per
module
Wide power supply range (9 - 32 V DC)
Wide ambient temperature range (- 30 °C - + 65°
C)
Compact size and lightweight
Extremely robust
Two-colour LED as status indicator
Available CANSAS measurement modules:
UNI-8
8-channel module for voltage, current, thermocouples,
PT100, strain gauges and measurement bridges; max sampling rate 1
kHz/channel.
C8
8-channel module for high precision temperature
measurement with thermocouple or PT100 or voltage measurement; max
sampling rate 100 Hz/channel.
BRIDGE2
2-channel measurement bridge module for quarter-,
half-, or full bridges, and strain gauges; max sampling rate 1
kHz/channel.
SC16
16-channel module for voltage, current, DIN
thermocouple or PT100 measurement; max sampling rate: 500
Hz/channel.
SCI8
8-channel module for of isolated voltage, current,
thermocouple or PT100 measurement; max sampling rate 1 kHz/channel.
INC4
4-channel module for connection of incremental
encoders with 2 tracks each. For displacement, angle, events, time,
frequency, velocity, RPM.
PWM8
8-channel Pulse Width Modulation output module; PWM-frequency
30 Hz – 10 kHz.
P8, P8-IP65
8-channel module for high precision pressure
measurement. Built-in barometer. Measurement modes:
relative/absolute pressure.
DAC8
8-channel analogue output module for voltage and
current sources (±10 V, 0 ... 20 mA)
DO8R/DO16R
8 or 16 channel digital output module with relays.
DO16
16-channel digital output module with 16 open
collector outputs.
DI16
16-channel digital input module with TTL or 24 V
range.
CANSAS
application areas
Road and rail vehicles, air and space craft,
manufacturing and power plants etc.
Anywhere a distributed measurement network is required to
transfer signals from a large area cheaply and noise-free to a central
location.
Implementation of analogue sensors on intelligent CANbus
networks
In cases requiring inexpensive, potential isolated
acquisition of many channels
Wherever conditions in the measurement's environment
require a compact, robust system capable of operating in an environment
with a wide temperature range, where conventional measurement equipment
is not an option.
CANSAS as a Personal Analyser
CANSAS
is also a Personal Analyser enabling the processing of measurement data
in real-time. In conjunction with a high-performance digital signal
processor (DSP) and the software interface, virtual channels can be set
up. The calculation instructions are entered using, conventional
mathematical notation. Virtual (computed) channels are treated just as
other channels. Performing additional data processing on the virtual
channels is also possible.
CANSAS Processing Functions
Basic arithmetic
Basic mathematical
functions such as: absolute value, value assignment, square root and
saw-tooth
Bitwise and normal
logical operators
Comparison functions
such as "Greater than" "Less than"
Statistics functions
such as "min., max., mean value, root-mean-square"
Functions governing
the housing LED's as status indicators
Conversion functions
Nonlinear filter
functions such as: hysteresis filter, median filter, slope limiting
Schmitt-trigger
linear filters such