Model Configuration |
| |
Universal Applications |
Special Applications |
| |
Multi-channel & Affordable |
High-resolution |
High-resolution, flexible voltage
measurement Isolated inputs |
All-purpose and powerful |
Affordable, quasi-static DC-measurements
with strain gauges |
Top quality, dynamic strain gauge |
DC/CF-measurement noise and vibration
analysis |
Power measurement |
 |
CS-1016 |
CS-1208 |
CS-4108 |
CS-7008 |
CS-5008 |
CS-6004 |
CS-8008 |
|
 |
CL-1032 |
CL-1224 |
CL-4124 |
CL-7016 |
CL-5016
CX-5032*
|
CL-6012 |
|
CL-2108 |
|
Analog inputs |
16 / 32 |
8 / 24 |
8 / 24 |
8 / 16 |
8 / 16 / 32 |
4 / 12 |
8 |
8 |
|
Differential inputs |
√ |
√ |
√ |
√ |
√ |
√ |
√ |
√ |
|
Isolated |
- |
- |
√ |
- |
- |
- |
- |
√√ (CAT III) |
|
Voltage |
√ |
√√ |
√ |
√√ |
√ |
√ |
√ |
√√ |
|
Current |
√ |
√ |
√ |
√ |
√ |
√ |
√ |
√√ |
|
Thermocouples |
- |
- |
√ |
√ |
- |
- |
- |
- |
|
PT100 |
- |
- |
√ |
√ |
- |
- |
- |
- |
|
Strain Gauges / bridges |
- |
- |
- |
√ |
√ |
√√ |
- |
- |
|
Bridge types and operation |
- |
- |
- |
1/4, 1/2, 1/1 DC |
1/4, 1/2, 1/1 DC |
1/4, 1/2, 1/1 DC/TF |
- |
- |
|
Current-fed sensors (ICP) |
o |
o |
o |
o |
o |
o |
√√ |
- |
|
Aggregate Sampling Rate |
320 KHz |
400 KHz |
400 KHz |
400 KHz |
400 KHz |
400 KHz |
400 KHz |
400 KHz |
|
Max. sampling rate / channel |
20 KHz |
100 KHz |
50 KHz |
100 KHz |
100 KHz |
20 KHz |
50 KHz |
100 KHz |
|
Bandwidth |
6.6 KHz |
14 KHz |
8 KHz |
14 KHz |
5 KHz |
8.6 KHz |
22.4 KHz |
17 KHz |
|
Input Ranges |
U: |
±250mV ... ±10V |
±5mV ... ±50V |
±50mV ... ±60V |
±5mV ... ±50V |
±5mV ... ±10V |
±5mV ... ±50V |
±25mV ... ±50V |
±2.5V ... 1000V |
|
I: |
±5mA ... ±50mA |
±100µA ... ±50mA |
±1mA ... ±40mA |
±100µA ... ±50mA |
±100µA ... ±50mA |
±100µA ... ±40mA |
- |
current input range depends on transducer |
|
Bridge: |
- |
- |
- |
±0.5mV/V ... ±1000mV/V |
±0.5mV/V ... ±1000mV/V |
±1mV/V ... ±2000mV/V |
- |
|
Sensor supply |
√ |
√ |
√ |
√√ |
√√ |
√ |
√ |
- |
|
TEDS |
√ |
√ |
√ |
√ |
√ |
in preparation |
√ |
√ |
|
CAN Interface, 2 nodes |
√ |
√ |
√ |
√ |
√ |
√ |
√ |
√ |
|
4 counter inputs |
√ |
√ |
√ |
√ |
√ |
√ |
√ |
√ |
|
8 digital inputs |
√ |
√ |
√ |
√ |
√ |
√ |
√ |
√ |
|
8 digital outputs |
√ |
√ |
√ |
√ |
√ |
√ |
√ |
√ |
|
4 analog outputs |
√ |
√ |
√ |
√ |
√ |
√ |
√ |
√ |
|
C-Series Hardware
Configuration |
| |
Housing Varieties |
| |
CS |
CL |
|
Network Interface |
|
|
|
Ethernet TCP/IP |
√ |
√ |
|
CAN-bus |
√ |
√ |
|
ECU-Protocols (such as KWP 2000, CCP, etc.) |
o |
o |
| |
|
|
|
Device synchronization |
|
|
|
Synchronous operation of mulitple devices by
means via sync-line |
√ |
√ |
|
CANSAS measurement module connection |
√ |
√ |
| |
|
|
|
Data Storage |
|
|
|
Slot for PCMCIA Solid State |
√ |
√ |
|
Slot for Compact Flash card |
o |
- |
|
Internal IDE hard drive |
- |
o |
| |
|
|
|
Displays |
|
|
|
Display built into device |
- |
√ |
|
Connection for external Display / Terminal |
√ |
- |
|
Hand-held terminal |
o |
- |
|
Hand-held terminal )Type L) |
o |
- |
|
B/W Display |
o |
- |
|
Colour Display |
o |
- |
| |
|
|
|
Data transfer, Remote Control |
|
|
|
Slot for PCMCIA WLAN card |
√ |
√ |
|
Connection for external modem* |
√ |
- |
|
Internal analog modem |
- |
o |
|
Internal ISDN modem |
- |
o |
|
Internal GSM radio modem |
- |
o |
| |
|
|
|
Radio Clock, GPS |
|
|
|
Connection for external DCF77 signal |
√ |
√ |
|
Device preperation for GPS mouse |
o |
o |
|
External GPS mouse |
o |
o |
|
External DCF77 real-time clock* |
o |
o |
|
IRIG-B |
in preparation |
in preparation |
| |
|
|
|
Ambient Conditions |
|
|
|
Operating temperature: -10°C ... +55°C |
√ |
√ |
|
Extended temperature range: -20°C ...
+60°C** |
o |
o |
|
Condensation protection |
o |
o |
| |
|
|
|
Power Supply |
|
|
|
10 - 36 VDC |
√ |
√ |
|
Network adapter 110V / 230V |
√ |
√ |
|
Battery buffer / UPS (buffer time) |
1s / power outage |
30s / power outage |
|
Selft activation following power outage |
√ |
√ |
|
Software Configuration
for all models |
| |
|
|
Universal applications |
|
|
imcDevices |
√ |
|
Total parameterization for CANSAS modules |
o |
|
ECU protocols for CAN interface |
o |
|
Vector database linkage |
o |
| |
|
|
Noise and Vibration analysis |
|
|
imcWave Order-tracking analyzer |
o |
|
imcWave Spectrum analyzer |
o |
|
imcWave Sound Power analyzer |
o |
|
imcWave Workplace Noise analyzer |
o |
|
imcWave Pass-by Noise analyzer |
o |
|
imcWave Structure analyzer |
o |
|
imcWave PersonalWave |
o |
| |
|
|
Network Quality Analysis |
|
|
imcPOLARES Software |
o |
| |
|
|
Online Software Options |
|
|
Online FAMOS |
√ |
|
Online FAMOS Professional* |
o |
|
Online Clas-counting package |
o |
|
Online Order-tracking analysis |
o |
| |
|
|
Measurement Data Analysis /
Administration |
|
|
imc FAMOS signal analysis software |
o |
|
imc Sensors sensor database |
o |
|
imc LOOK data visualization software |
o |
| |
|
|
Development Enviroment |
|
|
Development Enviroment |
o |
|
LabView™ interface, VI's |
√ |