Jump to:

Model Configuration
C-Series Hardware Configuration
Weight and Dimensions
Software Configuration
 
Model Configuration
  Universal Applications Special Applications
  Multi-channel & Affordable High-resolution High-resolution, flexible voltage measurement Isolated inputs All-purpose and powerful Affordable, quasi-static DC-measurements with strain gauges Top quality, dynamic strain gauge DC/CF-measurement noise and vibration analysis Power measurement
CS-1016 CS-1208 CS-4108 CS-7008 CS-5008 CS-6004 CS-8008  
CL-1032 CL-1224 CL-4124 CL-7016
CL-5016
CX-5032*
CL-6012   CL-2108
Analog inputs 16 / 32 8 / 24 8 / 24 8 / 16 8 / 16 / 32 4 / 12 8 8
Differential inputs
Isolated - - - - - - √√ (CAT III)
Voltage √√ √√ √√
Current √√
Thermocouples - - - - - -
PT100 - - - - - -
Strain Gauges / bridges - - - √√ - -
Bridge types and operation - - - 1/4, 1/2, 1/1 DC 1/4, 1/2, 1/1 DC 1/4, 1/2, 1/1 DC/TF - -
Current-fed sensors (ICP) o o o o o o √√ -
Aggregate Sampling Rate 320 KHz 400 KHz 400 KHz 400 KHz 400 KHz 400 KHz 400 KHz 400 KHz
Max. sampling rate / channel 20 KHz 100 KHz 50 KHz 100 KHz 100 KHz 20 KHz 50 KHz 100 KHz
Bandwidth 6.6 KHz 14 KHz 8 KHz 14 KHz 5 KHz 8.6 KHz 22.4 KHz 17 KHz
Input Ranges U: ±250mV ... ±10V ±5mV ... ±50V ±50mV ... ±60V ±5mV ... ±50V ±5mV ... ±10V ±5mV ... ±50V ±25mV ... ±50V ±2.5V ... 1000V
I: ±5mA ... ±50mA ±100µA ... ±50mA ±1mA ... ±40mA ±100µA ... ±50mA ±100µA ... ±50mA ±100µA ... ±40mA - current input range depends on transducer
Bridge: - - - ±0.5mV/V ... ±1000mV/V ±0.5mV/V ... ±1000mV/V ±1mV/V ... ±2000mV/V -
Sensor supply √√ √√ -
TEDS in preparation
CAN Interface, 2 nodes
4 counter inputs
8 digital inputs
8 digital outputs
4 analog outputs
√√ = high suitable
= default
o = optional
- = not available
* = The CX-5032 for 32-channel strain gauge measurement comes with a special housing (CX).

 

C-Series Hardware Configuration
 

Housing Varieties

  CS CL
Network Interface    
Ethernet TCP/IP
CAN-bus
ECU-Protocols (such as KWP 2000, CCP, etc.) o o
     
Device synchronization    
Synchronous operation of mulitple devices by means via sync-line
CANSAS measurement module connection
     
Data Storage    
Slot for PCMCIA Solid State
Slot for Compact Flash card o -
Internal IDE hard drive - o
     
Displays    
Display built into device -
Connection for external Display / Terminal -
Hand-held terminal o -
Hand-held terminal )Type L) o -
B/W Display o -
Colour Display o -
     
Data transfer, Remote Control    
Slot for PCMCIA WLAN card
Connection for external modem* -
Internal analog modem - o
Internal ISDN modem - o
Internal GSM radio modem - o
     
Radio Clock, GPS    
Connection for external DCF77 signal
Device preperation for GPS mouse o o
External GPS mouse o o
External DCF77 real-time clock* o o
IRIG-B in preparation in preparation
     
Ambient Conditions    
Operating temperature: -10°C ... +55°C
Extended temperature range: -20°C ... +60°C** o o
Condensation protection o o
     
Power Supply    
10 - 36 VDC
Network adapter 110V / 230V
Battery buffer / UPS (buffer time) 1s / power outage 30s / power outage
Selft activation following power outage
= default
o = optional
- = not available
* = external analog modem and external GPS mouse cannot be connected simultaneously
** = others upon request

 

Weight and Dimensions
  CS* CL**
Weight ca. 2 Kg ca. 3.5 Kg
Width 95 mm 250 mm
Height 111 mm 85 mm
Depth 185 mm 260 mm
*
For CS-8008, the folling values apply:
Weight: ca. 1.8 Kg, Width: 110 mm, Height: 120 mm, Depth: 195 mm
**
For CX-5032, the folling values apply:
Weight: ca. 7 Kg, Width: 286 mm, Height: 150 mm, Depth: 233 mm

 

Software Configuration for all models
   
Universal applications  
imcDevices
Total parameterization for CANSAS modules o
ECU protocols for CAN interface o
Vector database linkage o
   
Noise and Vibration analysis  
imcWave Order-tracking analyzer o
imcWave Spectrum analyzer o
imcWave Sound Power analyzer o
imcWave Workplace Noise analyzer o
imcWave Pass-by Noise analyzer o
imcWave Structure analyzer o
imcWave PersonalWave o
   
Network Quality Analysis  
imcPOLARES Software o
   
Online Software Options  
Online FAMOS
Online FAMOS Professional* o
Online Clas-counting package o
Online Order-tracking analysis o
   
Measurement Data Analysis / Administration  
imc FAMOS signal analysis software o
imc Sensors sensor database o
imc LOOK data visualization software o
   
Development Enviroment  
Development Enviroment o
LabView™ interface, VI's
= default
o = optional
* = Standard included with CL-2108 and imcWave