H2640/H2630 High Resolution Thermal Imaging Camera

  H2640 H2630
Measuring range
Range 1
Range 2
Range 3
Range 4
 
-40 to 500°C
-20 to 60°C
-40 to 120°C
0 to 500°C
200 to 2000°C
(optional: Display 0 to 2000°C)
-40 to 500°C
-40 to 120°C
0 to 500°C
200 to 2000°C
N/A
(optional: Display 0 to 2000°C)
Resolution
0.06°C or better (at 30°C, 30Hz)
0.03°C or better (at 30°C, ∑64)
0.08°C or better (at 30°C, 30Hz)
0.04°C or better (at 30°C, ∑16)
Accuracy ±2°C or ±2% of reading, whichever is greater
Detector Uncooled focal plane array (microbolometer)
Spectral range 8 to 13µm
I.F.O.V 0.6mrad
Focusing range 30cm to infinity
Field of view 21.7° (H) x 16.4° (V)
Display View finder and 5.6" movable colour LCD
Frame time 30 frames/sec
Thermal image pixels 640 (H) x 480 (V) pixels
A/D Resolution 14bits
Measuring functions Run/Freeze
S/N improvement ∑2, ∑8, ∑16, ∑32, ∑64 ∑2, ∑8, ∑16
Alarm Screen display and alarm sound (ON/OFF)
Movie recording Real-time memory:
up to 832 images (max. 30Hz)
N/A
Internal measurement Recording on built-in real-time memory: 1/30 to 3600 sec interval (H2640)
Recording on memory card: 5 to 3600 sec interval (thermal image)
30 to 3600 sec (thermal & visual images)
Trigger function provided
Emissivity correction Provided (0.10 to 1.00) Emissivity table provided.
Env. temp. correction Provided (including interval NUC)
User setup Pre-registration of environmental setup (up to 10 setups)
Background compensation Provided
Distance correction Provided
Auto functions Full automatic (level, sense, focus), Level trace, Auto-gain control
Thermal/visual image fusion Provided
Visible light camera 1.31 Mega pixels, colour, focusing distance:30cm to infinity
Display functions Display Colour: colour/monochrome, positive/negative
Graduation: 13, 32, 64, 128, 256
Colour palette: rainbow, brightness, shine, hot-iron, medical, fine
Isotherm band display: max. 4 bands, movable
Thumbnail display: 12 thermal images replay
Image rotation: 180° rotation
Multi-sense display: Battery life indicator
Waveform display: X-Y line waveform at Freeze mode
Multilingual menu
Digital Zoom x2, x4, x8 x2, x4
Multi-point temperature display Up to 10 points Up to 5 points
Multi-point emissivity correction Up to 10 points Up to 5 points
Image processing functions Variable level/sense
Multi-point temperature display (up to 10 points)
Multi-point temperature correction (up to 10 points)
Max/Min (peak hold) temperature display
Alarm (full screen or specified box)
Digital zoom 2, 4 , 8 times (Run/Freeze)
BOX setting, up to 5 boxes (max, min, average)
Temperature difference between 2 points (∆t)
Sharpness filter, Median filter, Average filter
Multi-focus*1
H2640 only
On/Off, temp threshold (1 to 100°C, 1°C step)
Images to capture (16 or 32), direction of edge
detection (horizontal, vertical, horizontal & vertical)
Annotation Text and voice annotation (30 secs per image)
Storage device Compact flash memory card for:
Thermal image in SIX or BMP file format
Visual image in SIX or JPEG file format
Video signal output NTSC/PAL, composite video signal, S-video
Interfaces USB 1.1/2.0 (mass staorage)
IEEE1394a
RS-232C
Compact flash memory card slot
Operating temperature -15 to 50°C, 90% RH or less (not condensed)
Storage temperature -40 to 70°C, 90% RH or less (not condensed)
Power supply AC adapter: 100 to 240V AC, 7.2V DC
Power consumption Approx. 9W typical
Shock and vibration 294m/s² (30G) (IEC60068-2-27), 29.4m/s² (3G) (IEC60068-2-6)
Environmental protection IP54 (IEC60529)
Dimensions 110 (W) x 110 (H) x 210 (D) mm
(excluding projection)
Weight 1.7Kg (including battery and LCD)
Standard accessories AC adapter, battery pack (2pcs), battery charger, CF memory card  and adapter, USB cable, lens cap, grip belt, neck strap, carrying case, operation manual, target illuminator
Software NS9200 Report Generator and NS9200LT NS9200LT Report Generator (Limited version)
*1 Image with multi-focus may not be obtained if there is little temperature differences.

Specifications are subject to change without prior notice.