Dali TE Thermal Imaging Camera

 

Specifications

Temperature ranges

-20°C ±250°C

Accuracy ±2°C or ±2% of reading which ever is greater
Measurement correction Automatic / Manual
Measurement mode Moveable spot
Colour palette 3 palettes changeable (Iron, rainbow, grey)

Image adjustment

Auto / manual gain and brightness
Setup functions Date / time, temperature unit, language
Emissivity correction Variable from 0.1 to 1.0
Ambient temperature correction Automatic correction according to user input
Detector Type Amorphous Silicon micro-bolometer
Array size/format 160 x 120
pixel pitch 25µm
Field of view/minimum focus distance 12° x 9°/0.3m
Spatial sensitivity 1.3mrad
Thermal sensitivity 0.12°C@30°C
Frame rate 50Hz
Focus Manual
Spectral range 8-14µm
LCD display Built-in high-resolution colour 2.5" LCD
Storage card Built-in flash memory. Up to 100 images
Storage mode Manual single image saving
File format-thermal JPEG, 14 bit thermal image with measurement data
Laser pointer Class 2, 1mw/635mm(red)
Battery type Li-Ion, rechargeable
Battery operating time 3 hours continuous operation
Charging system Intelligent charger
Power saving Yes
Operating temperature -15°C to +50°C
Humidity <90% (non-condensing)
Encapsulation IP54
Weight 0.6Kg
Dimensions 270mm x 100mm x 72mm
USB Image and measurement data transfer to PC
Specifications are subject to change without prior notice.