D-6 |
D-19 |
|
Detector Type |
Focal Plane Array FPA (Uncooled microbolometer) |
|
Spectral Range |
|
7.5 to 13µm |
|
Thermal Image Pixels |
160 x 120 pixels |
320 x 240 pixels |
|
Field of View |
52° (H) x 40° (V) with 6.3mm lens |
36° (H) x 27° (V) with 19mm lens |
|
I.F.O.V. |
6 mrad |
2 mrad |
|
Image Frequency |
7.5 Hz NTSC or 8.3 Hz PAL |
|
Focus |
Fixed |
|
Pan/Tilt |
|
Az Range / Az Velocity |
360° continuous; 0.5°/sec to 100°/sec |
|
El Range / El Velocity |
0° to 90°; 0.5°/sec to 100°/sec |
|
Programmable Presets |
32 |
|
Auto Scan |
1 path: scans linearly between 2 user-defined points |
|
Pattern |
1 route, up to 200 instructions |
|
Auto Flip |
Enabled |
|
Image Presentation |
|
Video Output |
PAL or NTSC |
|
Connector Types |
RS-485, Pelco-D |
|
Power |
|
Voltage |
24 VAC +/- 25% |
|
Power Consumption |
<20W |
|
Environmental / Physical |
|
Operating Temperature |
-10 to +50°C |
|
Humidity |
<90% RH, non-condensing. Indoor user only. Must be protected from
direct or indirect water spray |
|
Weight |
Pendant: 1.6Kg -ceiling mount configuration 3.0Kg |
|
Size |
Pendant: 200mm (H), 152mm Diameter Ceiling trim ring: 279.4mm Diameter |
|
Standard Package |
Thermal Imaging Camera, complete ceiling mount kit (trim ring and
back housing) and user manual |